Table 1 The detailed characteristics of the included studies

From: Evaluation of the loop-mediated isothermal amplification assay for Staphylococcus aureus detection: a systematic review and meta-analysis

Author

Year

Study design

Country

Source of specimens

Gold standard

Type of LAMP

Bacterial species

TP

FP

FN

TN

Su

2014

Prospective

China

Clinical

Culture and latex agglutinationa

orfX-LAMP

MRSA

557

0

9

101

Hanaki (a)

2011

Prospective

Japan

Clinical

PCR

LAMP

S. aureus

195

0

0

10

Hanaki (b)

2011

Prospective

Japan

Clinical

PCR

LAMP

MRSA

192

0

0

13

Metwally (a)

2014

Prospective

Egypt

Clinical

Standard proceduresb

LAMP

S. aureus

36

0

0

24

Metwally (b)

2014

Prospective

Egypt

Clinical

Standard proceduresb

LAMP

MRSA

19

0

0

41

Jiang (a)

2020

Prospective

China

Clinical

Culturec

m-LAMP-LFB

MRSA

8

0

0

88

Jiang (b)

2020

Prospective

China

Clinical

Culturec

m-LAMP-LFB

S. aureus

17

0

0

79

Kashani (a)

2020

Prospective

Iran

Clinical

Cultured

m-LAMP

S. aureus

49

0

0

4

Kashani (b)

2020

Prospective

Iran

Clinical

MIC and disk diffusion

m-LAMP

MRSA

37

4

0

12

Henares

2017

Prospective

Spain

Clinical

Cultured

eazyplex MRSA test system

S. aureus

5

1

1

44

Rödel (a)

2017

Prospective

Germany

Clinical

Routine species identificationd

eazyplex® MRSA

S. aureus

31

2

0

106

Rödel (b)

2017

Prospective

Germany

Clinical

Routine species identificationd

eazyplex® MRSA

MRSA

6

0

0

25

Nawattanapaiboon (a)e

2016

Prospective

Thailand

Clinical

Culturef

LAMP-LFD

MRSA

28

0

2

16

Nawattanapaiboon (b)

2016

Prospective

Thailand

Clinical

Culturef

LAMP-LFD

MRSA

52

0

0

20

Lim

2013

Prospective

Malaysia

Clinical

PCR

Loopamp DNA amplification kit

S. aureus

99

0

0

25

Leikeim (a)

2019

Retrospective

Germany

Clinical

Cultureg

eazyplex® MRSA and eazyplex® MRSA plus test strips

S. aureus

230

5

1

561

Leikeim (b)

2019

Prospective

Germany

Clinical

Cultureg

eazyplex® MRSA and eazyplex® MRSAplus

MRSA

32

2

0

763

Chen (a)

2020

Prospective

China

Clinical

Cultureh

m-LAMP-LFB

S. aureus

28

0

0

35

Chen (b)

2020

Prospective

China

Clinical

Cultureh

m-LAMP-LFB

MRSA

12

0

0

51

  1. aColony morphology, Gram staining, testing of catalase, hyaluronidase and coagulase, the Vitek 2 automated system and the API-Staph commercial kit
  2. bStandard microbiological methods along with MecA PCR
  3. cCulture, serum agglutination test and Gram stain
  4. dThe article is not described in detail
  5. eIt has two sets of data because they come from different samples
  6. fCoagulase and antimicrobial susceptibility test
  7. gConventional blood culture diagnostics
  8. hBlood culture, colony morphology, Gram staining, biochemical identification, and methicillin susceptibility testing