Skip to main content

Table 1 Antibody titers of the 150 clinically diagnosed typhoid fever cases in the first serum samples using 4 different Widal brands

From: The dilemma of widal test - which brand to use? a study of four different widal brands: a cross sectional comparative study

Widal

brand

Total No. of

positive samples (%)

No. of samples with given reciprocal titer

   

80

 

160

 

320

 

640

 

1280

 
 

O

H

O

H

O

H

O

H

O

H

O

H

Remel

131

(87.34)

141

(94.00)

23

14

42

60

45

32

19

25

2

10

Biosystems

129

(86.00)

136

(90.66)

32

15

47

60

35

35

13

18

2

8

Biotech

125

(83.34)

129

(86.00)

28

25

59

55

30

25

8

20

0

4

Dialab

103

(68.67)

106

(70.66)

46

42

49

41

8

22

0

1

0

0