Skip to main content

Table 2 blaKPC Real-time-PCR results compared with the MHT.

From: A rapid low-cost real-time PCR for the detection of klebsiella pneumonia carbapenemase genes

blaKPC Real- time-PCR*

MHT

Positive

Negative

Positive

29

0

Negative

0

130

  1. *: The percent sensitivity was 100 %, and the percent specificity was 100 %.
  2. Exact Sig. (2-tailed) =1.000; McNemar test.